| Model | Name | Instruction |
| A-01 | Meter Delayed | It will not regenerate although the available volume of treated water drops to zero (0). Regeneration will start at the regeneration time. |
| A-02 | Meter Immediate | Regenerate immediately when the available volume of treated water drops to zero(0). |
| A-03 | Intelligent Meter Delayed | Meter Delayed Regeneration type, by setting resin volume, feed water hardness, and regeneration factor, the controller will calculate the system capacity. |
| A-04 | Intelligent Meter Immediate | Meter Immediately Regeneration Type, by setting resin volume, feed water hardness, and regeneration factor, the controller will calculate the system capacity. |
- There are two kinds of regeneration modes for the time clock typeWhen the program is set to time clock type by days (Such as F63C1, F68C1, etc.) it can be changed to be by hours by dialing the red switch on the main control board to “1” (Refer to the figure in P18). Pointing to “ON” means the time clock type service by days. (Note: After dialing the switch, please restart the power)
- Interlock function
It has the interlock function to realize only one valve in regeneration but the other valves are in service while several valves are parallel in the system. In multi-step treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in regeneration or washing to ensure passing water all the time while different valves are in regeneration or washing.